ince 2013, Scala Filtration has been delivering quality compressed air purification equipment and laboratory liquid nitrogen generators around the world.
To lean more about latest technology and solution to compressed air treatment and liquid nitrogen generation,please contact us immediately.
Compressed Air Treatment & Liquid Nitrogen Generator
Language:
Home / All / Compressed Air Filter /
G Series high efficiency thread compressed air filter for air compressor
G Series high efficiency thread compressed air filter for air compressor
Detail Information
G Series high efficiency thread compressed air filter for air compressor
The new solution in Compressed air filtration
Compressed air contains harmful solid, liquid and vaporous contaminants that can damage pneumatic equipment, control and instruments. Removal of these contaminants is necessary to sustain equipment life and continue efficient production operation. Rust, scale and decay within compressed air system piping, and ambient air that contains gaseous and corrosive substances are common factor that contribute to the damaging effect of compressed air.
Compressed air purification equipment must deliver high quality air with the lowest cost of operation.
Very Low pressure drop means Energy Efficient
Inner automatic drain,differential pressure gauge
Inner threaded installation,easy to replace the element.
Pleated element, low pressure drop ,large filtration area.
Stainless steel and aluminum alloy hosing features high cooling effect.
Suitable for all compressed air application and all compressor type
Suitable for mineral and synthetic oil and oil free application
Silicon free ,safe for painting and surface coating applications
Electrophoresis treatment eliminating corrosion on internal and external head and bowl surfaces.
Scala elements are manufactured for lowest pressure drop and in accordance with International Standard for compressed air quality ISO8573.1:2001
SCALA'S filter element has the following advantages
Pleated filter elements provides a greater filtration volume than non-pleated. The large surface area and the low velocity, increase the space for holding contaminants,which reduce the differential pressure cased by retention of solid particles. The service life increase with a result of lower running cost.
Adopted with stainless steel diamond mesh which has larger filtration area and less pressure resistance compared to circular hole mesh.
Adopted with heat and corrosion resistant polyester wadding instead of traditional form. Form tears under high operational temperature causing the broken pieces to be carried over down stream.
No Pull rod design, saving installation space and very easy to change the element.
Elbow piping from air inlet to element which has smaller pressure drop compared to right angle piping.
Filtration Grade
|
Oil Removal
|
Particulate Removal | Initial Pressure Drop | Max.Inlet Temperature |
Grade P
|
N/A
|
3μm | 0.05bar | 100℃ |
Grade M
|
0.1ppm
|
1μm | 0.08bar | 100℃ |
Grade H
|
0.01ppm
|
0.01μm | 0.1bar | 100℃ |
Grade C
|
0.003ppm
|
N/A | 0.07bar | 60℃ |
Technical Specifications
Filter Model
|
Connection
|
Flow Capacity | Element Model | Dimensions(mm) |
Weight
|
||||
BSP
|
Nm3/min | cfm | A | B |
C
|
D |
Kg
|
||
G0055* | 1/2'' | 0.55 | 19 | 0055E* | 100 | 214 | 181 | 95 | 0.8 |
G0056* | 3/4'' | 0.55 | 19 | 0055E* | 100 | 214 | 181 | 95 | 0.8 |
G0120* | 1/2'' | 1.2 | 42 | 0120E* | 100 | 214 | 181 | 110 | 0.9 |
G0121* | 3/4'' | 1.2 | 42 | 0120E* | 100 | 214 | 181 | 110 | 0.9 |
G0200* | 3/4'' | 2 | 71 | 0200E* | 100 | 275 | 242 | 145 | 1.5 |
G0300* | 3/4'' | 3 | 106 | 0300E* | 100 | 275 | 242 | 175 | 1.6 |
G0350* | 1'' | 3.5 | 124 | 0350E* | 130 | 320 | 273 | 185 | 2.3 |
G0351*
|
1.1/2''
|
3.5 | 124 | 0350E* | 130 | 320 |
273
|
185 |
2.3
|
G0500*
|
1''
|
5 | 177 | 0500E* | 130 | 320 |
273
|
185 |
2.4
|
G0501* | 1.1/2'' | 5 | 177 | 0500E* | 130 | 320 | 273 | 185 | 2.4 |
G0750* | 1.1/2'' | 7.5 | 265 | 0750E* | 130 | 402 | 355 | 230 | 2.6 |
G1050* | 1.1/2'' | 10.5 | 371 | 1050E* | 130 | 402 | 355 | 270 | 2.7 |
G1450* | 2'' | 14.5 | 512 | 1450E* | 180 | 527 | 465 | 390 | 6.5 |
G1451* | 2.1/2'' | 14.5 | 512 | 1450E* | 180 | 527 | 465 | 390 | 6.5 |
G2200* | 2'' | 22 | 777 | 2200E* | 180 | 707 | 645 | 570 | 8.5 |
G2201* | 2.1/2'' | 22 | 777 | 2200E* | 180 | 707 | 645 | 570 | 8.5 |
G2500* | 2.1/2'' | 25 | 883 | 2500E* | 225 | 857 | 779 | 570 | 15 |
G2501* | 3'' | 25 | 883 | 2500E* | 225 | 857 | 779 | 570 | 15 |
G3000* | 2.1/2'' | 30 | 1059 | 3000E* | 225 | 857 | 779 | 630 | 15.2 |
G3001* | 3'' | 30 | 1059 | 3000E* | 225 | 857 | 779 | 630 | 15.2 |
G3002* | 4'' | 30 | 1059 | 3000E* | 225 | 857 | 779 | 630 | 15.2 |
G3500* | 3'' | 35 | 1236 | 3500E* | 225 | 1007 | 929 | 700 | 18 |
G3501* | 4'' | 35 | 1236 | 3500E* | 225 | 1007 | 929 | 700 | 18 |
G4500* | 3'' | 45 | 1589 | 4500E* | 225 | 1007 | 929 | 700 | 18.2 |
G4501* | 4'' | 45 | 1589 | 4500E* | 225 | 1007 | 929 | 700 | 18.2 |
G4900* | 4'' | 49 | 1730 | 4900E* | 225 | 1007 | 929 | 700 | 18.5 |
Note:
* Standards for filtration grades
* Max.working pressure 16barg (232psig)
Review
- Loading...
Related Products
Compressed air purification equipment
Just fill-in the form below and we will response to you within 24 hours.
- Tel
- *Title
- *Content
Navigation
News
- laboratory liquid nitrogen generator delivered to Tibet College of Agriculture and Animal HusbandryRecently, our company successfully supplied a self-developed laboratory liquid nitrogen generator for the Plant College of Tibet University of Agriculture and Animal Husbandry, with a liquid nitrogen output of > 20 liters per day.
- Hangzhou Scala officially launched silent laboratory liquid nitrogen generatorAs a professional laboratory liquid nitrogen solution provider, Hangzhou Scala recently officially launched a new integrated liquid nitrogen generator, the equipment is small, low noise, high degree of automation, easy to use and maintain. After more than a year of internal testing, all parameters have met the expected requirements.